Concept preview · in development · not for clinical use
VraiDose
VraiDose Audit · linac output

Audit linac output with a reading you get in the room.

Mailed dosimeters go back to a lab and the result arrives weeks later. VraiDose Audit is a shippable kit with a direct-readout detector: set it on the couch, align it to the lasers, deliver, and the measurement is recorded before the case ships back.

The VraiDose Audit detector with its 10 cm photon cap on a linac couch, aligned to the green room lasers The detector with an electron cap on the couch, cabled to the readout unit outside the field The detector on its alignment platform in the studio
Photon beams
6X · 10X · 15X · FFF
Electron beams
6 · 9 · 12 · 15 · 18 MeV
Readout
Direct · in the treatment room
Delivery
One ruggedised case
Why change the audit

Same audit question.
A faster, more direct answer.

Postal audits with passive dosimeters have served the field well. VraiDose Audit keeps the part that works, an independent measurement at a reference setup, and removes the wait between irradiation and result.

Mailed passive dosimetersVraiDose Audit
ReadoutAt a central lab, after the dosimeters are returned.Read directly while the detector is on the couch.
ResultDays to weeks after the irradiation.Recorded during the session, then reviewed centrally.
SetupChecked only through written instructions and photos.Printed crosshairs on the platform align to the room lasers; every run is logged.
RepeatsOne irradiation per dosimeter set.Repeat a delivery on the spot if something looks off.
EnergiesA holder per beam, per mailing.One detector; swap the depth cap for each photon or electron beam.

Design goals for a product in development. Not yet validated against a reference audit programme.

The kit

Four parts.
Nothing to calibrate on site.

Everything a physicist handles arrives in one case. The parts only fit together one way, so the setup is the same at every site.

The alignment platform with the detector block seated and an electron cap lifting off its guide pins
01

Alignment platform

Sits flat on the couch. Printed crosshairs line up with the room lasers and the light field.

The detector block on the platform with the 10 cm photon cap fitted
02

Detector block

Solid Water with the detector sealed inside. Drops into the platform pocket and connects on contact.

The six depth caps lined up from the thinnest electron cap to the 10 cm photon cap
03

Depth caps

One cap per beam sets the measurement depth. Each is labelled with its beam and depth.

The readout unit, a white powder-coated aluminium enclosure with a textured top
04

Readout unit

Powder-coated aluminium. Sits on the couch outside the field, cabled to the platform, and reads out over USB-C.

An electron depth cap lifted above the detector block, showing the four guide pins it seats on
Depth caps

One detector.
Every beam.

Four guide pins locate each cap over the detector, so changing beams is a ten-second swap with no realignment.

BeamDepthCap
Photons10.0 cm6X · 10X · 15X · FFF
6 MeVdrefe06
9 MeVdrefe09
12 MeVdrefe12
15 MeVdrefe15
18 MeVdrefe18

Electron caps are cut to the reference depth dref for each energy.

On site

Open the case.
Measure. Ship it back.

A short session on the treatment unit, guided by the card in the lid.

  1. 1

    Align

    Place the platform on the couch and match its crosshairs to the room lasers.

  2. 2

    Fit the cap

    Seat the detector block, then the depth cap for the beam you're auditing.

  3. 3

    Deliver

    Set a 10 × 10 cm field at isocentre and deliver the requested monitor units.

  4. 4

    Read and return

    The reading is captured as you deliver. Repack the foam and ship the case back.

Shipping

Built to travel
between clinics.

A latched hard case with cut foam for every part, numbered in the order you'll use them. If it doesn't sit flush in its pocket, something is missing.

The VraiDose Audit case open, every part seated in charcoal foam, with the quick-start card in the lid
Open case · quick-start card in the lid
Top view of the foam layout with numbered, engraved labels for each part
Numbered foam layout
Close-up of the depth caps standing in their labelled foam rack
Caps rack, labelled by energy

One case

Platform, detector, all six caps, cable and readout unit together.

Cut foam

A pocket for every part, with finger pulls to lift it out.

Engraved labels

Numbers in the foam match the steps on the lid card.

Repack check

An empty pocket shows at a glance before the case is closed.

Everything in the kit

Laid out.

The platform, detector block, photon cap, five electron caps, interconnect cable and readout unit.

Top-down view of every part in the kit laid out on a grey surface
Get in touch

Bring direct readout to your audits.

VraiDose Audit is in development. Tell us about your audit programme and we'll keep you posted as the kit takes shape.